Sign In | Join Free | My howtoaddlikebutton.com
China YUEMI logo
YUEMI
Guangzhou Yuemi Mechanical Seals Co., Ltd
Verified Supplier

2 Years

Home > Grundfos Pump Mechanical Seal >

Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal

YUEMI
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal

Brand Name : YUE MI

Model Number : GLF-SPK-12mm

Certification : ISO SGS

Place of Origin : Guangzhou, China

MOQ : 1/PCS

Price : US $ 13.8-23.8/PCS

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 1000/Set/Month

Delivery Time : 2 word days

Packaging Details : Details Carton

Traemark : YUE MI

Function : multi-stage pump

Shaft diameter : GLF-SPK-12mm

Secondary Sealing : Fkm EPDM TC TC

Type : slow-wire

Contact Now


Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality sealGrundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality sealGrundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal

Grunfos multi-stage pump slow wire mechanical seal, suitable for SPK2/4/8/16

Technical Parameters


Temperature -30℃~+200℃
pressure ≤2Mp a
Speed ≤10m/s
Medium water

Materials

Rotary Ring

SiC/VIT

Stationary Ring

SiC/VIT

Spring SUS304/SUS316
Stationary Seat SUS304/SUS316
Secondary Seal

Fkm/EPDM

Rotary Ring Holder SUS304/SUS316


Preperation:
1. Shaft Outside Diameter is within tolerance +-0.05mm
2. Shaft run out <0.1mm
3. Shaf end float <0.13mm
4, No sharp edges on the shaft over the o ring
Note:
During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.
Installation in strucstions:
1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

3. Place the cartridge seal into the pump chamber,then:
A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position
B : Tighter four set screws and position the shaft sleeve on the shaft.
C: Remove four gauge plates.Please keep them and they wil be used in future installation and
disassemble.
D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
flushing the seal chamber when pump running.
Note:
ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.


Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal

We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal

Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal


Product Tags:

OEM Grundfos Pump Mechanical Seal

      

12mm Grundfos Pump Mechanical Seal

      

Unbalanced grundfos pump seal

      
Wholesale Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal from china suppliers

Grundfos multi-stage pump slow-wire Mechanical Seal GLF-SPK-12mm SPK2/4/8/16 Good quality seal Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: YUEMI
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0